Luxuryade / Function configuration
PEMF and Red Light Therapy: A Mat Configuration Guide
Compare red light therapy mat configurations: red-only and red/NIR layouts, infrared heating and the measurements needed to assess light output.
In this guide

PEMF, red light therapy and heating use separate systems.
In a combined PEMF and red light therapy mat, coils generate changing magnetic fields and LEDs provide the light. A separate heating assembly warms the contact surface. A controller temperature, such as 30–70 °C, does not identify an LED wavelength or measured optical output.
NASA’s infrared reference places near-infrared outside visible light. Our dual-band platforms use visible 660 nm red LEDs and invisible 850 nm NIR LEDs. They can share the mat surface without sharing the heating assembly’s specifications.
Same LED total, different wavelength split.
| Model | 660 nm red | 850 nm NIR | Total |
|---|---|---|---|
| B190 | 156 | None in this configuration | 156 |
| G2613 | 96 | 60 | 156 |
| A063 | 66 | 88 | 154 |
| E2610 | 21 | 21 | 42 |
B190 and G2613 both total 156 LEDs. Only G2613 in this comparison has the red/NIR split. A063 has fewer total emitters than G2613 but more NIR emitters. Comparing total counts alone misses those differences.
LED counts: B Series, A Series and June 2026 Standard Catalog. These figures identify the standard configurations, not measured optical output.
Light is optional within the wider mat range.
| Model | PEMF | Light |
|---|---|---|
| G2613 | 6 coils · 3–64 Hz · 9 adjustable levels | 156 LEDs · 96 red / 60 NIR |
| B190 | 6 coils · 3–64 Hz · 9 adjustable levels | 156 LEDs · 660 nm red |
| A063 | 6 coils · 3–64 Hz · 9 adjustable levels | 154 LEDs · 66 red / 88 NIR |
| A7000 | 6 coils · 3–64 Hz · 9 adjustable levels | No photon LEDs in the standard configuration |
| LKT190 | Heating-only configuration | No photon LEDs |
A7000 combines heating, PEMF and TENS without photon LEDs. LKT190 is heating-only. A product name that includes “infrared” does not establish the presence of NIR LEDs.
Wavelength and count do not establish dose.
Optical irradiance describes power reaching a surface per unit area. NIST gives W/m² as the SI unit; mW/cm² is also commonly used in light-device specifications. For a constant irradiance, energy per area is irradiance multiplied by exposure time.
Illustrative calculation: 10 mW/cm² × 60 seconds = 600 mJ/cm² = 0.6 J/cm².
This is a unit example, not a measured Luxuryade output or a usage recommendation.
The actual light path depends on emitter output, position, distance, intervening mesh or cover and exposure time. Those conditions belong in any measurement record. Hamblin’s photobiomodulation review discusses dose-dependent responses; a larger LED count cannot be translated directly into a greater clinical benefit.
Physical-unit reference: NIST SP 330.
Review the light layout and controls together.
For an existing model, use its wavelength split and layout as the starting specification. For a custom version, identify which wavelengths, positions and controls should change. Include the controller labels and instructions in the same review.
Visible brightness is not a function test for 850 nm NIR. Agree the required check method and any quantitative output evidence for the actual sample. Our sample checklist separates those questions from an appearance review. For a branded range, include the LED layout, controller and packaging in your private-label OEM brief.
Sources & product references
The model comparisons use our listed catalog configurations. Sample checks and project-planning recommendations are Luxuryade factory guidance; they are not clinical research findings.
Catalog basis: June 2026 Standard Catalog; A Series; B Series; PEMF LK Mat Catalog.